Require 3 readings for same status before changing thermal status
  • Loading branch information
Pekka Lundstrom committed Apr 23, 2014
2 parents 7f20327 + 7679107 commit 387931c
Show file tree
Hide file tree
Showing 3 changed files with 60 additions and 26 deletions.
80 changes: 54 additions & 26 deletions modules/thermalmanager.c
Expand Up @@ -214,18 +214,19 @@ static void receive_temperature_response(thermal_object_t* thermal_object,
}
#endif

/* heuristics to convert to degrees C */
if (temperature > 1000) {
/* convert from millidegrees to degrees */
temperature = temperature / 1000;
}
if (temperature > 223) { /* 223 K ~ -50 degrees C */
/* convert from kelvin to degrees celsius */
temperature = temperature - 273;
/* We require that temp readings are C degrees integers
* and we drop obviously wrong values
*/
if ((temperature > 200) || (temperature < -50)) {
dsme_log(LOG_WARNING,
"thermalmanager: invalid temperature reading: %s %dC",
thermal_object->conf->name,
temperature);
return;
}

/* figure out the new thermal object status based on the temperature */
if (temperature < thermal_object->conf->state[new_status].min) {
if (temperature < thermal_object->conf->state[new_status].min) {
while (new_status > THERMAL_STATUS_LOW &&
temperature < thermal_object->conf->state[new_status].min)
{
Expand All @@ -238,26 +239,44 @@ static void receive_temperature_response(thermal_object_t* thermal_object,
++new_status;
}
}
thermal_object->status = new_status;

#ifndef DSME_THERMAL_LOGGING
dsme_log(LOG_DEBUG,
"thermalmanager: %s temperature: %d %s",
thermal_object->conf->name,
temperature,
thermal_status_name[thermal_object->status]);
#endif

if (new_status != previous_status) {
/* thermal object status has changed*/

/* see if the new status affects global thermal status */
THERMAL_STATUS previously_indicated_status = current_status;
current_status = worst_current_thermal_object_status();

if (current_status != previously_indicated_status) {
/* global thermal status has changed; send indication */
send_thermal_indication(thermal_object->conf->name, temperature);
thermal_status_name[new_status]);

if ((new_status != previous_status) || thermal_object->status_change_count) {
/* Thermal object status has changed, but it can be because of bad reading.
* Before accepting new status, make sure it is not a glitch.
We want 3 consecutive readings indicating same status before we change it.
*/
if (thermal_object->status_change_count == 0) {
/* This is first reading for new status */
thermal_object->status_change_count = 1;
thermal_object->new_status = new_status;
dsme_log(LOG_DEBUG,
"thermalmanager: New status in transition started");
} else {
/* We are in transition. Make sure all new readings want same status */
if (thermal_object->new_status != new_status) {
thermal_object->status_change_count = 0;
dsme_log(LOG_DEBUG,
"thermalmanager: New status in transition did not remain same");
} else if (++(thermal_object->status_change_count) >= 3) {
/* We got 3 readings all indicating new status, better believe it */
dsme_log(LOG_DEBUG,
"thermalmanager: New status accepted: %s", thermal_status_name[new_status]);
thermal_object->status = new_status;
thermal_object->status_change_count = 0;
/* see if the new status affects global thermal status */
THERMAL_STATUS previously_indicated_status = current_status;
current_status = worst_current_thermal_object_status();
if (current_status != previously_indicated_status) {
/* global thermal status has changed; send indication */
send_thermal_indication(thermal_object->conf->name, temperature);
}
}
}
}

Expand All @@ -277,8 +296,17 @@ static void thermal_object_polling_interval_expired(void* object)
&thermal_object->conf->state[thermal_object->status];

DSM_MSGTYPE_WAIT msg = DSME_MSG_INIT(DSM_MSGTYPE_WAIT);
msg.req.mintime = conf->mintime;
msg.req.maxtime = conf->maxtime;
/* If thermal status is in transition and we are taking several
* readings before change, then use speed up values for
* next readings. Otherwise use configured values
*/
if (thermal_object->status_change_count) {
msg.req.mintime = 2;
msg.req.maxtime = 5;
} else {
msg.req.mintime = conf->mintime;
msg.req.maxtime = conf->maxtime;
}
msg.req.pid = 0;
msg.data = thermal_object;

Expand Down
2 changes: 2 additions & 0 deletions modules/thermalmanager.h
Expand Up @@ -62,6 +62,8 @@ typedef struct thermal_object_configuration_t {
struct thermal_object_t {
thermal_object_configuration_t* conf;
THERMAL_STATUS status;
THERMAL_STATUS new_status;
int status_change_count;
bool request_pending;
};

Expand Down
4 changes: 4 additions & 0 deletions modules/thermalobject_hw.c
Expand Up @@ -57,6 +57,8 @@ static thermal_object_configuration_t core_thermal_conf = {
static thermal_object_t core_thermal_object = {
&core_thermal_conf,
THERMAL_STATUS_NORMAL,
THERMAL_STATUS_NORMAL,
0,
0
};

Expand All @@ -79,6 +81,8 @@ static thermal_object_configuration_t battery_thermal_conf = {
static thermal_object_t battery_thermal_object = {
&battery_thermal_conf,
THERMAL_STATUS_NORMAL,
THERMAL_STATUS_NORMAL,
0,
0
};

Expand Down